IMU-MGE
8KV EFT/Burst, SURGE, Ringwave and 10/700us impulse generator
Compact generator for EFT/Burst, SURGE, 100 kHz Ringwave and 10/700 impulses up to 8KV. Integrated 16 A CDN. Extend with ESD, Dips/Interrupts and Common Mode.
Modular test generator with colour touch screen and intuitive software. An integrated help with graphics guide the user through fast and efficient setup and operation. Each generator can be extended on site with up to 10 test types. Configurations for IEC / EN and ANSI test requirements can include Surge (CWG), 100 kHz Ringwave, 10/700 and EFT all up to 8kV. DIPS/Interrupts, variations, Common Mode, Differential Mode and ESD further enhance the generator creating a compact test solution. A test library of basic and generic requirements is included as standard. The integrated web server enables access to test report and setup files from any internet browser.
Pulses
- Surge / CWG up to 8kV
- Ring Wave up to 8kV
- Telecom up to 8kV
- EFT / Burst up to 8kV
- Common Mode 35V/330V
- AC & DC Interrupts up to 16A
- AC DIPS & Variations up to 16A
- Differential mode testing
- ESD up to 16kV
Documents
Conducted ImmunityYour Benefits
- Compact test generator
- One touch parameter editing in run state
- Impulse stability over long periods
- Intuitive multi touch graphical interface
- Upgradeable hardware to increase test capability
- Test report in three user selectable formats
Features:
- 6 kV or 8 kV Impulses
- Integrated Variac
- Integrated Common Mode
- Control of ESD
- Control of Differnetial Mode
- AC & Impulse Magnetic Fields
- DIPS / Interrupts & Variations
ANSI/IEEE C37.90 | Relays and Relay Systems Associated with Electric Power Apparatus |
IEC 61000-4-2 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-4 | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques |
IEC 61000-4-5 | Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test |
IEC 61000-4-8 | Electromagnetic compatibility (EMC) |
IEC 61000-4-9 | Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test |
IEC 61000-4-11 | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-12 | Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test |
IEC 61000-4-16 | Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
IEC 61000-4-19 | Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports |
IEC 61000-4-29 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 61000-4-34 | Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase |
ITU-T K.20 | Resistibility of telecommunication equipment installed in a telecommunication centre to overvoltages and overcurrents |
ITU-T K.21 | Resistibility of telecommunication equipment installed in customer premises to overvoltages and overcurrents |
ITU-T K.44 | Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation |